6 servopack main circuit wire size, 1 cable types, 6 servopack main circuit wire size -12 – Yaskawa SGDH Linear Sigma Series User Manual

Page 140: 1 cable types -12

Advertising
background image

6 Specifications and Dimensional Drawings of Cables and Peripheral Devices

6.6.1 Cable Types

6-12

6.6 SERVOPACK Main Circuit Wire Size

1. Wire sizes were selected for three cables per bundle at 40

°C (104 °F) ambient temperature with the rated

current.

2. Use cable with a minimum withstand voltage of 600 V for main circuits.
3. If cables are bundled in PVC or metal ducts, consider the reduction ratio of the allowable current.
4. Use heat-resistant cables under high ambient or panel temperatures where normal vinyl cables will rap-

idly deteriorate.

5. Use cables within the allowable mass.
6. Do not use cables under continuous regenerative state.

6.6.1 Cable Types

The following table shows the wire size and allowable current for three cables. Use a cable whose specifications
meet or are less than the values in the table.

• 600-V Heat-resistant Vinyl Cables (HIV)

Note: The values in the table are only for reference.

IMPORTANT

Cable Types

Allowable

Conductor

Temperature

°C (°F)

Symbol

Name

PVC

Normal vinyl cable

IV

600-V vinyl cable

60 (140)

HIV

Temperature-resistant
vinyl cable

75 (167)

AWG Size

Nominal

Cross

Section

Diameter

mm

2

Configuration

Number of
wires/mm

2

Conductive

Resistance

Ω/km

Allowable Current at Ambient Temperature

A

30

°C (86

°

F)

40

°C

(104

°

F)

50

°C

(122

°

F)

20

0.5

19/0.18

39.5

6.6

5.6

4.5

-

0.75

30/0.18

26.0

8.8

7.0

5.5

18

0.9

37/0.18

24.4

9.0

7.7

6.0

16

1.25

50/0.18

15.6

12.0

11.0

8.5

14

2.0

7/0.6

9.53

23

20

16

12

3.5

7/0.8

5.41

33

29

24

10

5.5

7/1.0

3.47

43

38

31

8

8.0

7/1.2

2.41

55

49

40

6

14.0

7/1.6

1.35

79

70

57

4

22.0

7/2.0

0.85

91

81

66

Advertising