6 positioning near signal, 6 positioning near signal -58 – Yaskawa SGDH Linear Sigma Series User Manual

Page 302

Advertising
background image

9 Operation

9.8.6 Positioning Near Signal

9-58

9.8.6 Positioning Near Signal

This signal indicates that the positioning of the linear servomotor is near to completion, and is generally used in
combination with the positioning completed (/COIN) output signal.
The host controller receives the positioning near signal prior to confirming the positioning-completed signal, and
performs the following operating sequence after positioning has been completed to shorten the time required for
operation.

Type

Signal

Name

Connector

Pin Number

Setting

Meaning

Output

/NEAR

Must be allocated

ON (low level)

The servomotor has reached a point near to positioning
completed.

OFF (high level) The servomotor has not reached a point near to posi-

tioning completed.

The output terminal must be allocated with parameter Pn510 in order to use positioning near signal. Refer to 8.3.3 Output
Circuit Signal Allocation
for details.

Pn504

NEAR Signal Width

Setting Range

Setting Unit

Factory Setting

Setting Validation

1 to 250

Reference units

7

Immediately

The positioning near (/NEAR) signal is output when the differ-
ence (error) between the number of reference pulses output by
the host controller and the travel distance of the servomotor is
less than the value set in Pn504.
Set the number of error pulses in reference units (the number of
input pulses defined using the electronic gear.)
Normally, the setting should be larger than that for the position-
ing completed width (Pn500).

Position

Speed

Reference

Motor speed

Error pulse

/NEAR

/COIN

Pn504

Pn500

0