12.4 List of Parameters

12-31

12

* Available for the software version 32 or later

Parameter

No.

Name

Setting Range

Unit

Factory

Setting

Setting

Validation

Reference

Section

Pn217

Reference Pulse Input Multiplication *

1 to 99

×

1

1

Immedi-

ately

Pn218

Reference Pulse Input Multiplication
Function Selection *

0000

After

restart

Pn280

Linear Scale Pitch

0 to 65535

1

μm

0

After

restart

9.2.2
9.2.3
9.7.7
9.8.2

Pn281

PG Divider

1 to 255

1P/(scale

pitch)

20

After

restart

9.7.7

Pn300

Speed Reference Input Gain

150 to 3000

0.01V

/ rated

speed

600

Immeci-

ately

9.7.1
9.9.4

Pn305

Soft Start Acceleration Time

0 to 10000

1 ms

0

Immedi-

ately

9.7.4

Pn306

Soft Start Deceleration Time

0 to 10000

1 ms

0

Immedi-

ately

9.7.4

Pn307

Speed Reference Filter Time Constant

0 to 65535

0.01 ms

40

Immedi-

ately

9.7.5

Pn308

Speed Feedback Filter Time Constant

0 to 65535

0.01 ms

0

Immedi-

ately

10.4.7

Pn380

Internal Set Speed 1

0 to 5000

1 mm/s

10

Immedi-

ately

9.10.1

Pn381

Internal Set Speed 2

0 to 5000

1 mm/s

20

Immedi-

ately

9.10.1

Pn382

Internal Set Speed 3

0 to 5000

1 mm/s

30

Immedi-

ately

9.10.1

Pn383

JOG Speed

0 to 5000

1 mm/s

50

Immedi-

ately

Pn384

Motor Maximum Speed *

1 to 100

0.1 m/s

50

After

restart

9.6.6

Pn400

Force Reference Input Gain

10 to 100

0.1 V/

rated force

30

Immedi-

ately

9.9.1
9.9.2

10.4.2

Pn401

Force Reference Filter Time Constant

0 to 65535

0.01 ms

100

Immedi-

ately

10.4.10

Pn404

Forward External Force Limit

0 to 800

1%

100

Immedi-

ately

9.11.2
9.11.4

Pn405

Reverse External Force Limit

0 to 800

1%

100

Immedi-

ately

0

1

Disabled

Enabled

Reference Pulse Multiplication Function Selection

4th

digit

3rd

digit

2nd

digit

1st

digit

n.

Reserved (Do not change)

Reserved (Do not change)

Reserved (Do not change)