9.10 Operating Using Speed Control with an Internally Set Speed

9-65

9

9.10 Operating Using Speed Control with an Internally Set Speed

• Internally Set Speed Selection

This function allows speed control operation by externally selecting an input signal from among three servo-
motor speed settings made in advance with parameters in the SERVOPACK. The speed control operations
within the three settings are valid. There is no need for an external speed or pulse generator.

9.10.1 Setting Parameters

Note: The maximum speed of linear servomotor is used whenever a speed settings for the Pn380 to

Pn382 exceed the maximum speed.

SERVOPACK

41

45

46

Pn380

SPEED1

Pn381

SPEED2

Pn382

SPEED3

Internally set speed
parameters

Speed
reference

Linear
Servomotor

M

Contact inputs

/P-CON (/SPD-D)

/P-CL

(/SPD-A)

/N-CL (/SPD-B)

CN1

Parameter

Meaning

Pn000

n.

††

3

†

Control mode selection: Internally set speed control (contact reference)

Pn380

Internally set speed 1 (SPEED1)

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 5000

1 mm/s

10

Immediately

Pn381

Internally set speed 2 (SPEED2)

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 5000

1 mm/s

20

Immediately

Pn382

Internally set speed 3 (SPEED3)

Setting Range

Setting Unit

Factory Setting

Setting Validation

0 to 5000

1 mm/s

30

Immediately

Speed

Speed

Speed