7.5.4 Operating Conditions on 400-V Power Supply Voltage

There are three types of SGDH SERVOPACKs, for the power supply voltages: Single-phase 200 VAC, three-
phase 200 VAC, and three-phase 400 VAC. When using the SERVOPACK for 200 V with the three-phase 400-
VAC class (380 to 480 V), prepare the following voltage conversion transformers (single-phase or three-phase)

When selecting a voltage conversion transformer, refer to the capacities shown in the following table.

* This is the net value at the rated load.

Single-phase Power Supply Connection Example

• Do not connect the SERVOPACK for 200 V directly to a voltage of 400 V.

The SERVOPACK will be destroyed.

• Control the AC power supply ON and OFF sequence at the primary side of voltage conversion transfer.

Voltage conversion transfer inductance will cause a surge voltage if the power is turned ON and OFF at the secondary,
damaging the SERVOPACK.

CAUTION

Primary Voltage

Secondary Voltage

380 to 480 VAC

→

200 VAC

Voltage

SERVOPACK Model

SGDH-

Voltage Capacity per

SERVOPACK * (kVA)

Current Capacity of Circuit

Breaker or Fuse (Arms)

Single-phase
200 V

A5AE

0.25

4

01AE

0.40

02AE

0.75

04AE

1.2

8

Three-phase
200 V

05AE

1.4

4

08AE

1.9

7

10AE

2.3

15AE

3.2

10

20AE

4.3

13

30AE

5.9

17

50AE

7.5

28

75AE

15.5

41

Single-phase

Magnetic contactor for
power supply ON and OFF

Voltage conversion
transformer

200 VAC

SERVOPACK

R

S

T

1KM

1KM

L1

L2