8.2 Operation in Utility Function Mode (Fn†††)

8-11

8

The linear servomotor movement direction differs depending on the setting of parameter Pn000.0 “Direction
Selection.” The above example shows the case of factory setting.

8.2.4 Zero-point Search Mode (Fn003)

The zero-point search mode is designed to perform positioning to the zero-point pulse (phase-C) position of the
linear scale that outputs the zero-point signal and to clamp at the position.
This mode is used to confirm that the linear scale outputs the zero-point signal correctly.
When the maximum speed is set to 5 m/s, the movement speed for executing the zero-point search is 60 mm/s.
The following conditions must be met to perform the zero-point search operation.

• If the Servo-ON input signal (/S-ON) is ON, turn it OFF.
• Release the Servo-ON signal mask if the parameter Pn 50A.1 is set to 7, and the servo has been set to

always be ON.

Follow the procedure below to execute the zero-point search.

INFO

• Forward run prohibited (P-OT) and reverse run prohibited (N-OT) signals are disabled during zero-point

search mode operations using Fn003.

CAUTION

Step

Display after

Operation

Digital Operator

Panel Operator

Description

1

Press the DSPL/SET or MODE/SET Key to select
the utility function mode.

2

Press the UP or DOWN Key to select the Fn003.

Note: The enabled digit blinks.

3

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second, and the display will
be as shown on the left.

4

Press the SVON or MODE/SET Key.
The servo turns ON.

5

When the parameter is set to Pn000.0 = 0 (default),
pressing the UP Key will run the motor in the for-
ward direction. Pressing the DOWN Key will run the
motor in the reverse direction. When the parameter
is set to Pn000.0 = 1, the movement direction of the
motor is reversed.

6

Display blinks.

When the motor zero-point search is completed, the
display blinks.
At this moment, the motor is servo-locked at the
zero-point pulse position.

7

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second.
Fn003 display appears again.
The motor will be servo OFF status.

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

JOG

SVON

(SVON Key)

MODE/SET

(MODE/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

Advertising