10.4.3 Speed Feed-forward

Parameter

Meaning

Pn207

n.

††

0

†

Disabled

n.

††

1

†

Uses V-REF terminal for speed feed-forward input.

Pn300

Speed Reference Input Gain

Setting Range

Setting Unit

Factory Setting

Setting Validation

150 to 3,000

(1.50 to 30.00 V/Rated

speed)

0.01 V/Rated

speed

600

(6.00 V/Rated speed)

Immediately

The speed feed-forward function uses analog voltages and is valid only in position control.
The speed feed-forward function is used to shorten positioning time. The host controller differentiates the position refer-
ence to generate the feed-forward reference, and inputs the feed-forward reference together with the position reference to
the SERVOPACK.
Too high a speed feed-forward value will result in overshooting or undershooting. To prevent such troubles, set the opti-
mum value while observing the system responsiveness.
Connect a position reference signal line to PULS and SIGN (CN1-7, -8, -11, and -12) and a speed feed-forward reference
signal line to V-REF (CN1-5 and -6) from the host controller.

Speed feed-forward value is set using the parameter Pn300.
The factory setting is Pn300 = 600. If, for example, the speed feed-forward value is

±

6V, then the speed is limited to the

rated speed.

Speed

Position

Force

Pn100

M

PG

K

FF

+

-

+

+

V-REF (CN1-5 and -6)

+

Kp ( Pn102 )

+

-

Position

reference

Current loop

Speed

calculation

Integration

(Pn101)

Linear

servomotor

Linear

scale

Host controller

SERVOPACK

Kp: Position loop gain
K

FF

: Feed-forward gain

Differ-

ential

Pn300

PULS
SIGN