10 motor models display (fn011), 10 motor models display (fn011) -17 – Yaskawa SGDH Linear Sigma Series User Manual

Page 225

Advertising
background image

8.2 Operation in Utility Function Mode (Fn†††)

8-17

8

8.2.10 Motor Models Display (Fn011)

This mode is used for motor maintenance, set the parameter Fn011 to select the motor model check mode. If the
SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.

Step

Display after

Operation

Digital Operator Panel Operator

Description

1

Press the DSPL/SET or MODE/SET Key to select the
utility function mode.

2

Press the UP or DOWN Key to select Fn011.

Note: The enabled digit blinks.

3

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to display the linear ser-
vomotor model and voltage code.

4

Press the DSPL/SET or MODE/SET Key to display the
servomotor capacity.

5

Press the DSPL/SET or MODE/SET Key, and the linear
scale type and resolution code will be displayed.

6

Press the DSPL/SET or MODE/SET Key to display the
SERVOPACK’s code for custom orders.

Note: The display “y.0000” means standard model.

7

Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the utility
function mode display Fn011.

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

Linear Servomotor Voltage

Data

Model

Type

01
02

200 VAC or 280 VDC
400 VAC or 560 VDC

Linear Servomotor Type

Data

Linear servomotor

40

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

Motor capacity in units of 10 W

The above example indicates 100 W.

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

Scale Pitch Multiplication

Data

Resolution

8-bit

8

Linear Scale Type

Data

Type

Incremental

00

DSPL

SET

(DSPL/SET Key)

MODE/SET

(MODE/SET Key)

Code for custom orders

DATA

ENTER

(DATA/ENTER

Key)

DATA

(DATA/SHIFT Key)

(Press at least 1 s.)

Advertising