6 interface circuit, 6 interface circuit -29, 1) interface for reference input circuits – Yaskawa SGDH Linear Sigma Series User Manual

Page 193: A) analog input circuit, B) position reference input circuit

Advertising
background image

7.4 Examples of I/O Signal Connections

7-29

7

7.4.6 Interface Circuit

This section shows examples of SERVOPACK I/O signal connection to the host controller.

(1) Interface for Reference Input Circuits

(a) Analog Input Circuit

CN1 connector terminals, 5-6: Speed reference input and 9-10: Force reference input are explained below.
Analog signals are either speed or force reference signals at the impedance below.

• Reference speed input: About 14 k

Ω

• Reference force input: About 14 k

Ω

The maximum allowable voltages for input signals is

±

12 V.

(b) Position Reference Input Circuit

CN1 connector terminals, 7-8: Reference pulse input, 11-12: Reference code input and 15-14: Clear input are
explained below.
An output circuit for the reference pulse and position error pulse clear signal at the host controller can be
either line-driver or open-collector outputs. The following shows by type.

Analog Voltage Input Circuit

Analog Voltage Input Circuit (D/A)

1.8 k

Ω (1/2 W)min.

25HP-10B

2 k

Ω

3

2

12 V

1

0 V

SG

About 14 k

Ω

SERVOPACK

V-REF or

T-REF

0 V

SG

Host controller

About 14 k

Ω

SERVOPACK

V-REF or

T-REF

D/A

Line-driver Output Circuit

Open-collector Output, Example 1:

Power Supply Provided by User

Open-collector Output, Example 2:

Using 12-V Power Supply Built into SERVOPACK

150

Ω

4.7 k

Ω

2.8 V

≤ (H level) - (L level) ≤ 3.7 V

Applicable line driver
SN75174 manufactured
by Texas Instruments
or the equivalent

Host controller

SERVOPACK

V

F

= 1.5 to 1.8 V

Vcc

Tr1

V

F

R1

i

150

Ω

4.7 k

Ω

Use the examples below to set pull-up resistor R1 so the input
current, i, falls between 7 mA and 15 mA.

Application Examples

R1 = 2.2 k

Ω with a

Vcc of 24 V

±

5%

R1 = 1 k

Ω with a

Vcc of 12 V

±

5%

R1 = 180

Ω with a

Vcc of 5 V

±

5%

Host controller

SERVOPACK

PL1, PL2, PL3 terminals

0 V

+12 V

1.0 k

Ω

150

Ω

1.5 V max.
when ON

About
9 mA

Host controller

SERVOPACK

Advertising