1 overload characteristics, 1 overload characteristics -12 – Yaskawa SGDH Linear Sigma Series User Manual

Page 110

Advertising
background image

4 SERVOPACK Specifications and Dimensional Drawings

4-12

4.5 SERVOPACK Overload Characteristics and Allowable Load Mass

4.5.1 Overload Characteristics

SERVOPACKs have a built-in overload protective function that protects the SERVOPACKs and servomotors
from overload. Allowable power for the SERVOPACKs is limited by the overload protective function as shown
in the figure below.

The overload detection level is set under hot start

1

conditions at a servomotor ambient temperature of 40

°C

(104

°F).

1

Hot Start

A hot start indicates that both the SERVOPACK and the servomotor have run long enough at the rated load to be thermally
saturated.

TERMS

10,000

1,000

100

10

5

1

Operating time (s)

Rated force Approx.

Rated force

+

Maximum force

2

Maximum force

Motor force

Advertising