1.3 Examples of Servo System Configurations

1-9

1

1.3.2 Three-phase, 200 V Main Circuit

Regenerative
resistor

Noise filter

Molded-case
circuit breaker
(MCCB)

Magnetic
contactor

I/O signal cable

Power supply
Three-phase 200 VAC

R S T

Protects the power
supply line by shutting
the circuit OFF when
an overcurrent is
detected.

Eliminates external noise
from the power line.

Connect an external
regenerative resistor
to terminals B1 and B2
if the regenerative
capacity is insufficient.

Turns the servo
ON and OFF.
Install a surge
suppressor.

(Refer to 2.6.1.)

(Refer to 2.6.4.)

(Refer to 2.6.5.)

(Refer to
2.6.3.)

(Refer to 2.6.3.)

(Refer to 2.6.2.)

Connection cable for
digital operator

Connection cable for
personal computer

(Refer to 2.6.1.)

Linear servomotor with core

Linear scale
(To be provided by
users)

Encoder
cable

Main circuit cable for
linear servomotor

Serial converter unit

Connection cable for
serial converter unit

(Refer to 2.5.)

(Refer to 2.5.)

(Refer to 2.5.)

(Refer to 2.5.)

(Refer to 2.4.)

Personal computer

Host controller

L1

L2

L3

U

V

W

L1C
L2C
B1
B2
B3

1

2

C

N
3

C
N
1

C
N
2

MODE/SET

DATA/

CHARGE

POWER

YASKAWA

SERVOPACK

SGDH-

200V

*1
*3

*2

*3: To connect a DC reactor, refer to 7.5.5 DC Reactor for Harmonic
Suppression.

*1: The positive terminal for the main circuit is only available for use
in the three-phase (200 VAC, 7.5 kW) SERVOPACKs.
Do not use the positive terminals 1 or 2.

*2: Before connecting an external regenerative resistor to
the SERVOPACK, be sure to disconnect the lead between terminals
B2 and B3.

Digital

operator

(Refer to 2.6.1.)

SGDH-††AE

SERVOPACK

Connection cable
for hall sensor

Advertising