6 example of conn – Yaskawa SGDH Linear Sigma Series User Manual

Page 397

Advertising
background image

12.3 Connection to Host Controller

12-21

12

12.3.6 Example of Connection to Mitsubishi’s AD72 Positioning Unit

(SERVOPACK in Speed Control Mode)

* 1. The ALM signal is output for about two seconds after the power is turned ON. Take this into consid-

eration when designing the power ON sequence. The ALM signal actuates the alarm detection relay
1Ry to stop the main circuit power supply to the SERVOPACK.

* 2. Pin numbers are the same both for X-axis and Y-axis.
* 3. Connect the connector wire to the connector shell.

* 4.

represents twisted-pair wires.

Note: Only signals applicable to Mitsubishi’s AD72 Positioning Unit and Yaskawa’s SGDH SERVO-

PACK are shown in the diagram.

43

42

1Ry

+

-

+24V

I/O power supply

0

24

V

+24 V

CONT

SERVO

CN1

ENCO

CN1

STOP
DOG

SV-ON

READY

PULSE A

PULSE C

PULSE B

0V

0V

0V

∗2

1

3

2

1

3

2

4

6

5

4

7

5

8

11

10

3

9

6

1

+24V-IN

P-OT

N-OT

ALM+

ALM-

V-REF (T-REF)

SG

PAO

SG

/PCO

PCO

/PBO

PBO

/PAO

47

32

31

40

1

20

19

34

33

36

35

5(9)
6(10)

/S-ON

1Ry

∗4

0

24

V

Positioning unit
AD72 manufactured
by Mitsubishi

SGDH SERVOPACK

Speed reference

ON when

positioning

is cancelled.

ON when

proximity

is detected.

∗3

Connector

shell

L1C

L3

L2

L1

L2C

Control power supply

Main circuit power supply

CN2

W

V

U

Linear servomotor

Linear scale

Properly treat the ends of shielded wires.

M

PG

Serial

converter

unit

Advertising