9 dc reactor for harmonic suppression, 9 dc reactor for harmonic suppression -28, 1) specifications – Yaskawa SGDH Linear Sigma Series User Manual
Page 156

6 Specifications and Dimensional Drawings of Cables and Peripheral Devices
6.8.9 DC Reactor for Harmonic Suppression
6-28
6.8.9 DC Reactor for Harmonic Suppression
(1) Specifications
If necessary for harmonic suppression, connect a DC reactor to the SERVOPACK. Note that no terminal for con-
necting a DC reactor is provided to the 7.5 kW SERVOPACKs.
Refer to the table below for selecting a DC reactor according to the SERVOPACK capacity. For the connection
method, refer to 6.8.9 DC Reactor for Harmonic Suppression.
Applicable
SERVOPACK Model
SGDH-
DC Reactor
Model
DC Reactor Specifications
Inductance
(mH)
Rated
Current
(A)
Single-phase
200 V
A5AE
−
−
−
01AE
X5071
40.0
0.85
02AE
X5070
20.0
1.65
04AE
X5069
10.0
3.3
Three-phase
200 V
05AE
X5061
2.0
4.8
08AE
10AE
15AE
X5060
1.5
8.8
20AE
30AE
X5059
1.0
14.0
50AE
X5068
0.47
26.8
Three-phase
400 V
05DE
X5074
4.7
1.5
10DE
X5075
3.3
4.5
15DE
20DE
X5076
2.2
8.6
30DE
50DE
X5077
1.5
14.1