9 dc reactor for harmonic suppression, 9 dc reactor for harmonic suppression -28, 1) specifications – Yaskawa SGDH Linear Sigma Series User Manual

Page 156

Advertising
background image

6 Specifications and Dimensional Drawings of Cables and Peripheral Devices

6.8.9 DC Reactor for Harmonic Suppression

6-28

6.8.9 DC Reactor for Harmonic Suppression

(1) Specifications

If necessary for harmonic suppression, connect a DC reactor to the SERVOPACK. Note that no terminal for con-
necting a DC reactor is provided to the 7.5 kW SERVOPACKs.
Refer to the table below for selecting a DC reactor according to the SERVOPACK capacity. For the connection
method, refer to 6.8.9 DC Reactor for Harmonic Suppression.

Applicable

SERVOPACK Model

SGDH-

DC Reactor

Model

DC Reactor Specifications

Inductance

(mH)

Rated

Current

(A)

Single-phase
200 V

A5AE

01AE

X5071

40.0

0.85

02AE

X5070

20.0

1.65

04AE

X5069

10.0

3.3

Three-phase
200 V

05AE

X5061

2.0

4.8

08AE
10AE
15AE

X5060

1.5

8.8

20AE
30AE

X5059

1.0

14.0

50AE

X5068

0.47

26.8

Three-phase
400 V

05DE

X5074

4.7

1.5

10DE

X5075

3.3

4.5

15DE
20DE

X5076

2.2

8.6

30DE
50DE

X5077

1.5

14.1

Advertising