11 Inspection, Maintenance, and Troubleshooting

11.1.2 Warning Display

11-4

* 1. These alarm occur only for the software version 32 or later.
* 2. For the SERVOPACK with a capacity of 7.5 kW:

A.40: Alarm detecting excessively high/low voltage in the main circuit
A.41: Not used

11.1.2 Warning Display

The relation between warning displays and warning code outputs is shown in table 11.2.

* The warning occurs only for the software version 32 or higher.
Note: Warning code is not output without setting Pn001 = n.1††† (Outputs both Alarm Codes and

Warning Codes.)

A.F1

Power Line Open Phase

One phase is not connected in the
main power supply.

Available

H

L

H

H

A.F6

Servomotor Line Disconnection

*1

The power is not supplied to the linear
servomotor while the SERVOPACK
received a servo ON command.

Available

CPF00

Digital Operator
Transmission Error

Digital operator (JUSP-OP02A-2)
fails to communicate with SERVO-
PACK (e.g., CPU error).

N/A

Not decided

CPF01

N/A

A.

− −

Not an error

Normal operation status

H

H

H

L

Table 11.1 Alarm Displays and Outputs (Cont’d)

Alarm

Display

Alarm Name

Meaning

Alarm
Reset

Alarm Code Output

Servo
Alarm

(ALM)

Output

ALO1

ALO2

ALO3

Table 11.2 Warning Displays and Outputs

Warning

Display

Warning Name

Meaning

Warning Code Output

ALO1

ALO2

ALO3

A.90

Excessive Position Deviation * The position deviation exceeds the value of Pn51E.

H

H

H

A.91

Overload

This warning occurs before the overload alarms (A.71 or
A.72) occur. If the warning is ignored and operation con-
tinues, an overload alarm may occur.

L

H

H

A.92

Regenerative Overload

This warning occurs before the regenerative overload
alarm (A.32) occurs. If the warning is ignored and opera-
tion continues, a regenerative overload alarm may occur.

H

L

H