10-6

the port is considered as “Down”.

 In order to make sure that neighbors can be correctly created and unidirectional links can be correctly

discovered, it is required that both end of the link should enable ULDP, using the same authentication

method and password. At present, no password is needed on both ends.

 The hello interval of sending hello messages can be changed (it is10 seconds by default and ranges

from 5 to 100 seconds) so that ULDP can respond faster to connection errors of links in different

network environments. But this interval should be less than 1/3 of the STP convergence time. If the

interval is too long, a STP loop will be generated before ULDP discovers and shuts down the

unidirectional connection port. If the interval is too short, the network burden on the port will be

increased, which means a reduced bandwidth.

 ULDP does not handle any LACP event. It treats every link of TRUNK group (like Port-channal, TRUNK

ports) as independent, and handles each of them respectively.

 ULDP does not compact with similar protocols of other vendors, which means users can not use ULDP

on one end and use other similar protocols on the other end.

 ULDP function is disabled by default. After globally enabling ULDP function, the debug switch can be

enabled simultaneously to check the debug information. There are several DEBUG commands

provided to print debug information, such as information of events, state machine, errors and messages.

Different types of message information can also be printed according to different parameters.

 The Recovery timer is disabled by default and will only be enabled when the users have configured

recovery time (30-86400 seconds).

 Reset command and reset mechanism can only reset the ports automatically shut down by ULDP. The