2 efm oam configuration, Onfiguration – PLANET XGS3-24042 User Manual

Page 119

Advertising
background image

14-4

4. Remote loopback testing

Remote loopback testing is available only after an Ethernet OAM connection is established. With remote

loopback enabled, operating Ethernet OAM entity in active mode issues remote loopback requests and the

peer responds to them. If the peer operates in loopback mode, it returns all packets except Ethernet

OAMPDUs to the senders along the original paths. Performing remote loopback testing periodically helps to

detect network faults in time. Furthermore, performing remote loopback testing by network segments helps to

locate network faults. Note: The communication will not be processed normally in remote loopback mode.

Typical EFM OAM application topology is in the following, it is used for point-to-point link and emulational

IEEE 802.3 point-to-point link. Device enables EFM OAM through point-to-point connection to monitor the link

fault in the First Mile with Ethernet access. For user, the connection between user to telecommunication is

“the First Mile”, for service provider, it is “the Last Mile”.

Customer

Service Provider

Customer

CE

PE

802.1ah OAMPDU

802.3ah
Ethernet in
the First Mile

Figure 14-2 Typical

OAM application topology

14.2 EFM OAM Configuration

EFM OAM configuration task list

1. Enable EFM OAM function of port

2. Configure link monitor

3. Configure remote failure

4. Enable EFM OAM loopback of port

Note: it needs to enable OAM first when configuring OAM parameters.

1. Enable EFM OAM function of port

Command

Explanation

Port mode

Advertising