3 ulsm typical example, Ulsm, Ypical – PLANET XGS3-24042 User Manual

Page 610: Xample

Advertising
background image

68-3

68.3 ULSM Typical Example

Figure 68-2 ULSM typical example

The above topology is the typical application environment which is used by ULSM and ULPP protocol.

ULSM is used to process the port state synchronization, its independent running is useless, so it usually

associates with ULPP protocol to use. In the topology, SwitchA enables ULPP protocol, it is used to switch the

uplink. SwitchB and SwitchC enable ULSM protocol to monitor whether the uplink is down. If it is down, then

ULSM will execute the down operation for the downlink port to shutdown it, so ULPP protocol of Swtich A

executes the relative operation of the uplink switchover.

SwitchA configuration task list:

Switch(Config)#spanning-tree mst configuration

Switch(Config-Mstp-Region)#instance 1 vlan 1

Switch(Config-Mstp-Region)#exit

Switch(Config)#ulpp group 1

Switch(ulpp-group-1)#protect vlan-reference-instance 1

Switch(ulpp-group-1)#exit

Switch(Config)#interface ethernet 1/0/1

Switch(config-If-Ethernet1/0/1)# ulpp group 1 master

Switch(config-If-Ethernet1/0/1)#exit

Switch(Config)#interface Ethernet 1/0/2

Switch(config-If-Ethernet1/0/2)# ulpp group 1 slave

Switch(config-If-Ethernet1/0/2)#exit

SwitchB configuration task list:

Switch(Config)#ulsm group 1

Switch(Config)#interface ethernet 1/0/1

SwitchB E1/0/1

SwitchD

SwitchA

E1/0/2 SwitchC

E1/0/2

E1/0/1

E1/0/3

E1/0/4

Advertising
This manual is related to the following products: