14-7

CE

PE

802.1ah OAMPDU

Ethernet

1/0/1

Ethernet

1/0/1

Figure 14-3 Typical

OAM application topology

Configuration procedure: (Omitting SNMP and Log configuration in the following)

Configuration on CE:

CE(config)#interface ethernet 1/0/1

CE (config-if-ethernet1/0/1)#ethernet-oam mode passive

CE (config-if-ethernet1/0/1)#ethernet-oam

CE (config-if-ethernet1/0/1)#ethernet-oam remote-loopback supported

Other parameters use the default configuration.

Configuration on PE:

PE(config)#interface ethernet 1/0/1

PE (config-if-ethernet1/0/1)#ethernet-oam

Other parameters use the default configuration.

Execute the following command when using remote loopback.

PE(config-if-ethernet1/0/1)#ethernet-oam remote-loopback

Execute the following command to make one of OAM peers exiting OAM loopback after complete

detection.

PE(config-if-ethernet1/0/1)# no ethernet-oam remote-loopback

Execute the following command without supporting remote loopback.

CE(config-if-ethernet1/0/1)#no ethernet-oam remote-loopback supported

14.4 EFM OAM Troubleshooting

When using EFM OAM, it occurs the problem, please check whether the problem is resulted by the following

reasons:

 Check whether OAM entities of two peers of link in passive mode. If so, EFM OAM connection can not

be established between two OAM entities.

 Ensuring SNMP configuration is correct, or else errored event can not be reported to network

management system.

 Link does not normally communicate in OAM loopback mode, it should cancel remote loopback in time

after detect the link performance.

 Ensuring the used board supports remote loopback function.
 Port should not configure STP, MRPP, ULPP, Flow Control, loopback detection functions after it enables

OAM loopback function, because OAM remote loopback function and these functions are mutually