Chapter 62 ULSM Configuration

71-3

Port Mode

sflow counter-interval <interval-vlaue>

no sflow counter-interval

Configure the max interval when sFlow

performing statistic sampling. The “no” form of

this command deletes

8. Configure the analyzer used by sFlow

Command

Explanation

Port Mode

sflow analyzer sflowtrend

no sflow analyzer sflowtrend

Configure the analyzer used by sFlow, the no

command deletes the analyzer.

71.3 sFlow Examples

Figure

71-1

sFlow configuration topology

As shown in the figure, sFlow sampling is enabled on the port 1/0/1 and 1/0/2 of the switch. Assume the sFlow

analysis software is installed on the PC with the address of 192.168.1.200. The address of the layer 3

interface on the SwitchA connected with PC is 192.168.1.100. A loopback interface with the address of

10.1.144.2 is configured on the SwitchA. sFlow configuration is as follows:

Configuration procedure is as follows:

Switch#config

Switch (config)#sflow ageng-address 10.1.144.2

Switch (config)#sflow destination 192.168.1.200

Switch (config)#sflow priority 1

Switch (config)# interface ethernet1/0/1

Switch (Config-If-Ethernet1/0/1)#sflow rate input 10000

Switch (Config-If-Ethernet1/0/1)#sflow rate output 10000

Switch (Config-If-Ethernet1/0/1)#sflow counter-interval 20

Switch (Config-If-Ethernet1/0/1)#exit

Switch (config)# interface ethernet1/0/2

Switch (Config-If-Ethernet1/0/2)#sflow rate input 20000

Switch (Config-If-Ethernet1/0/2)#sflow rate output 20000

Switch (Config-If-Ethernet1/0/2)#sflow counter-interval 40

SWITCH

PC