14-3

need to wait until it receives the connection request. After an Ethernet OAM connection is established, the

Ethernet OAM entities on both sides exchange Information OAMPDUs continuously to keep the valid Ethernet

OAM connection. If an Ethernet OAM entity receives no Information OAMPDU for five seconds, the Ethernet

OAM connection is disconnected.

2. Link Monitoring

Fault detection in an Ethernet is difficult, especially when the physical connection in the network is not

disconnected but network performance is degrading gradually. Link monitoring is used to detect and discover

link faults in various environments. EFM OAM implements link monitoring through the exchange of Event

Notification OAMPDUs. When detecting a link error event, the local OAM entity sends an Event Notification

OAMPDU to notify the remote OAM entity. At the same time it will log information and send SNMP Trap to the

network management system. While OAM entity on the other side receives the notification, it will also log and

report it. With the log information, network administrators can keep track of network status in time.

The link event monitored by EFM OAM means that the link happens the error event, including Errored symbol

period event, Errored frame event, Errored frame period event, Errored frame seconds event.

Errored symbol period event: The errored symbol number can not be less than the low threshold. (Symbol:

the min data transmission unit of physical medium. It is unique for coding system, the symbols may be

different for different physical mediums, symbol rate means the changed time of electron status per second. )

Errored frame period event: Specifying N is frame period, the errored frame number within the period of

receiving N frames can not be less than the low threshold. (Errored frame: Receiving the errored frame

detected by CRC.)

Errored frame event: The number of detected error frames over M seconds can not be less than the low

threshold.

Errored frame seconds event: The number of error frame seconds detected over M seconds can not be less

than the low threshold. (Errored frame second: Receiving an errored frame at least in a second.)

3. Remote Fault Detection

In a network where traffic is interrupted due to device failures or unavailability, the flag field defined in Ethernet

OAMPDUs allows an Ethernet OAM entity to send fault information to its peer. As Information OAMPDUs are

exchanged continuously across established OAM connections, an Ethernet OAM entity can inform one of its

OAM peers of link faults through Information OAMPDUs. Therefore, the network administrator can keep track

of link status in time through the log information and troubleshoot in time.

There are three kinds of link faults for Information OAMPDU, they are Critical Event, Dying Gasp and Link

Fault, and their definitions are different for each manufacturer, here the definitions are as below:

Critical Event: EFM OAM function of port is disabled.

Link Fault: The number of unidirectional operation or fault can not be less than the high threshold in local.

Unidirectional Operation means unidirectional link can not work normally on full-duplex link without

autonegotiaction. EFM OAM can detect the fault and inform the remote OAM peers through sending

Information OAMPDU.

Dying Gasp: There is no definition present. Although device does not generate Dying Gasp OAMPDU, it still

receives and processes such OAMPDU sent by its peer.