5.4 MP2000 Series Machine Controller Parameter Details

5.4.2 Motion Setting Parameter Details

5-42

( 32 ) Absolute Infinite Length Axis Position Control Information

( 33 ) Various Data

OL

5E

Encoder Position when Power is OFF

(Lower 2 words)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

Description

This is the information for infinite length axis position control when an absolute encoder is used.

The encoder position is stored in 4 words.
If the Request ABS Rotary Pos. Load bit is set to 1 in the Run Command Setting (setting parameter OW

00, bit 7), the

position information will be recalculated with the values set here and the Pulse Position when Power is OFF (OL

62

and OL

64).

Refer to 10.4 Absolute Position Detection for Infinite Length Axes on page 10-14 for details.
Set to 0 for linear type.

OL

60

Encoder Position when Power is OFF

(Upper 2 words)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

Description

Same as for OL

5E.

Refer to

10.4 Absolute Position Detection for Infinite Length Axes on page 10-14 for details.

Set to 0 for linear type.

OL

62

Pulse Position when Power is OFF (Lower 2 words)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

Description

This is the information for infinite length axis position control when an absolute encoder is used.

The axis position in pulses managed internally by the controller is stored in 4 words.
If the Request ABS Rotary Pos. Load bit is set to 1 in the Run Command Setting (setting parameter OW

00, bit 7), the

position information will be recalculated with the values set here and the Encoder Position When Power is OFF
(OL

5E and OL

60).

Refer to 10.4 Absolute Position Detection for Infinite Length Axes on page 10-14 for details.
Set to 0 for linear type.

OL

64

Pulse Position when Power is OFF (Upper 2 words)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

pulse

0

Description

Same as for OL

62.

Refer to 10.4 Absolute Position Detection for Infinite Length Axes on page 10-14

for details.

Set to 0 for linear type.

OL

66

Monitor Data Command

Setting Range

Setting Unit

Default Value

0

Description

Reserved for system use. Do not use this parameter.

OL

68

Writing Data Type

Setting Range

Setting Unit

Default Value

0 to 3

0

Description

Reserved for system use. Do not use this parameter.

OL

6A

Monitor Address

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

0

Description

Reserved for system use. Do not use this parameter.

OL

6C

Writing Data

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

0

Description

Reserved for system use. Do not use this parameter.

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Advertising