12.2 Troubleshooting System Errors
12.2.4 System Register Configuration and Error Status
12-25
12
Troubleshooting
[ c ] MP2300 Machine Controller
[ d ] SVA-01 Module Information
• Module ID = 9093H
• SVA Function Module ID = 9013H
9093H will be written as Module ID, and 9013H as Function Module ID in the SVA-01 Module mounted slot descrip-
tion.
For example, when an SVA-01 Module is mounted in Slot 1 of Rack 1,
SW00816 = 9093H
SW00820 = 9013H
Name
Register No.
Description
Module
Information
SW00800
Basic Module (C380H)
SW00801
Reserved by the system
SW00802
CPU Software version (BCD)
SW00803
Number of subslots (0004H)
SW00804
CPU Function Module ID (C310H)
SW00805
CPU Function Module status
SW00806
I/O Function Module ID (8070H)
SW00807
I/O Function Module status
SW00808
SVB Function Module ID (9113H)
SW00809
SVB Function Module status
SW00810
SVR Function Module ID (9210H)
SW00811
SVR Function Module status
SW00812 to SW00815
Reserved by the system
SW00816 to SW00823
Slot 1 Information
SW00824 to SW00831
Slot 2 Information
SW00832 to SW00839
Slot 3 Information
...
SW01008 to SW01015