2 overtravel function, 1 ) overtravel input signal connections – Yaskawa JAPMC-MC2300 User Manual

Page 308

Advertising
background image

11.2 Overtravel Function

11.2.1 Connections to

Σ-II/Σ-III/Σ-V Series SGDH, SGDS, or SGDV SERVOPACK

11-8

11.2 Overtravel Function

The overtravel function forces the machine to stop when the moving part of the machine exceeds the range of move-
ment. With the MP2000-series Machine Controller, processing for stopping as a result of overtravel is achieved by
using SERVOPACK functions.
The SERVOPACK connections and parameter setting depend on the model of SERVOPACK. The connections and
parameter settings are described in the following sections.

11.2.1 Connections to

Σ-II/Σ-III/Σ-V Series SGDH, SGDS, or SGDV SERVOPACK

The following parameters must be set to ensure the overtravel input signals are connected correctly for the overtravel
function.

( 1 ) Overtravel Input Signal Connections

Correctly connect the input signals for the overtravel limit switches shown below to the corresponding pins on the
SERVOPACK CN1 or 1CN connector.

P-OT

When ON
CN1-42 is low.

Forward drive enabled.
Normal operating condition

When OFF
CN1-42 is high.

Forward drive disabled.
(Reverse movement possible.)

N-OT

When ON
CN1-43 is low.

Reverse drive enabled.
Normal operating condition

When OFF
CN1-43 is high.

Reverse drive disabled.
(Forward movement possible.)

Forward rotation

Reverse rotation

SERVOPACK

CN1-42

CN1-43

N-OT

P-OT

Servomotor

Negative

overtravel

Positive

overtravel

Advertising