Yaskawa JAPMC-MC2300 User Manual

Page 354

Advertising
background image

12.4 Troubleshooting Motion Errors

12.4.3 Analog Servo Alarm List

12-35

12

Troubleshooting

A.bF0

System Alarm 0
(Internal program processing
error)

A SERVOPACK program error (internal program error 0) occurred.

A.bF1

System Alarm 1
(Internal program operating
error)

A SERVOPACK program error (internal program error 1) occurred.

A.bF2

System Alarm 2
(Program error in current control
processor)

A SERVOPACK program error (internal program error 2) occurred.

A.bF3

System Alarm 3
(Error in Encoder interface
processor)

A SERVOPACK program error (internal program error 3) occurred.

A.bF4

System Alarm 4
(CPU WDT error)

A SERVOPACK program error (internal program error 4) occurred.

A.C10

Servo Run-away

The Servomotor was overrunning.

A.C80

Encoder Clear Error Multiturn Limit
Setting Error

The absolute encoder's multiturn count was cleared or it could not be set
properly.

A.C90

Encoder Communication Error

Communications could not be established between the Encoder and SER-
VOPACK.

A.C91

Encoder Communication
Position Data Acceleration Error

An error occurred in the encoder's position data calculation.

A.C92

Encoder Communication
Timer Error

An error occurred in the timer used for communications between the
Encoder and SERVOPACK.

A.CA0

Encoder Parameter Error

The Encoder's parameters are corrupted.

A.Cb0

Encoder Echoback Error

The contents of communications with the encoder are incorrect.

A.CC0

Multiturn Limit Mismatch

The Encoder and SERVOPACK Multiturn Limit Values do not agree.

A.d00

Excessive Position Error

The position error pulses exceeded the setting in parameter Pn520.

A.d01

Excessive Position Error Alarm at
Servo ON

When the Servo went ON, the position error pulse count exceeded the
value set in parameter Pn 526.

A.d02

Excessive Position Error Alarm for
Speed Limit at Servo ON

The speed limit in parameter Pn529 is applied if the Servo goes ON and the
position error pulse count was excessive. Reference pulses were input in
that condition and the value set in parameter Pn520 was exceeded without
clearing the speed limit.

A.F10

Broken Phase in Power Line

One phase of the three-phase main power supply is not connected.

CPF00

Digital Operator
Communications Error

Communications could not be established between the JUSP-OP05A Digi-
tal Operator and SERVOPACK due to a CPU Error or other problem.

CPF01

A.

− −

No error display

Indicates normal operating status.

Code

Alarm Name

Alarm Content

Advertising