11.3 Software Limit Function

11.3.3 Axis Stopping Operation at Alarm Occurrence

11-14

11.3.3 Axis Stopping Operation at Alarm Occurrence

The way the axis stops at occurrence of alarm differs depending on the motion command that is being executed as
shown in the table below.

The software limit settings is disabled for ZRET operation.

11.3.4 Processing after an Alarm Occurs

( 1 ) Monitoring Alarms

If an axis exceeds a software limit, a Positive/Negative Soft Limit (Positive/Negative Software Limit) alarm will occur.
This alarm can be monitored in the monitoring parameter (IL

04).

( 2 ) Clearing Software Limit Alarms

Clear software limit alarms using the procedure below.

1.

Set the Clear Alarm bit to 1 in the RUN Command Setting (OW

00, bit F) to clear the alarm.

The alarm (IL

04) will be cleared.

2.

Use the FEED or STEP command to return past the software limit.

Motion Command

Stop Operation

POSING
EX_POSING
FEED
STEP

The axis will start decelerating before the software limit position and stop
at the software limit position.

INTERPOLATE
ENDOF_INTERPOLATE
LATCH

The pulse distribution command will stop executing at the software limit
position. The Servo will perform an emergency stop.

VELO
TRQ
PHASE

The axis will start decelerating the software limit position and stop
beyond the software limit position.

Name

Parameter No.

Meaning

Alarm

IL

04

Bit 3:

Positive Direction Software Limit

Bit 4:

Negative Direction Software Limit

Name

Parameter No.

Meaning

RUN Command Setting

OW

00

Bit F:

Alarm Clear

Commands will be received in the return direction.

Servo-

motor

An alarm will occur again if a command is

given in the direction of the software limit

that was activated.

Software Limit,

lower limit

Software Limit,

upper limit

Advertising