( 3 ) Maximum Number of Absolute Encoder Turns Rotation/Multiturn Limit Setting

These parameters determine the maximum value of the number of encoder turns managed by the SERVOPACK and
Machine Controller.

For an infinite length axis, set the parameters as shown in the table below.

* If the Machine Controller fixed parameter 38 is set to 65535 when using a

Σ-II, Σ-III, or Σ-V series SERVOPACK for

an infinite axis, a fixed parameter setting error will occur.

Applicable

SERVOPAC

K

Fixed Parameter 38

(Maximum Number of Absolute Encoder

Turns Rotation)

SERVOPACK

Parameter Pn205

(Multiturn Limit Setting)

Σ-II/Σ-III/Σ-V Series

Set the same value as Pn205 *

65534 max.

*

Σ-I Series

99999