2 ) setting example 2 – Yaskawa JAPMC-MC2300 User Manual

Page 140

Advertising
background image

6.1 Example Setting of Motion Parameters for the Machine

6.1.8 Linear Scale Pitch and Rated Motor Speed

6-16

( 2 ) Setting Example 2

The following tables give setting examples for these linear motor, linear scale, and SERVOPACK specifications.

Linear Motor Specifications

• Rated motor speed

: 1.5 (m/s)

Linear Scale and SERVOPACK Specifications

• Linear scale pitch

: 25.6 (

μm)

• Serial converter resolution

: 256 (division)

For SGDM, SGDH, SGDS, and SGDV SERVOPACKs, the set value of SERVOPACK parameter Pn281
(Encoder Output Resolution) is actually used in place of the serial converter resolution.

• Pn281 (Encoder Output Resolution): 8 (pulses/(scale pitch

×

4)

Set Pn281 to a value of multiples of 4.

[ a ] Setting Example when Fixed Parameter No. 4 (Reference Unit Selection) is Set to 1: mm

[ b ] Setting Example when Fixed Parameter No. 4 (Reference Unit Selection) is Set to 0: pulse

Fixed Parameter

Setting Unit

Set Value

Description

No. 4

Reference Unit
Selection

–

mm

The actual reference unit is determined by settings of this
parameter and the number of digits below decimal point (fixed
parameter 5).
When Number of Digits below Decimal Point = 4,
1 reference unit = 0.0001 (mm) = 0.1 (

μm)

No. 5

Number of Digits
below Decimal
Point

–

4

When Number of Digits below Decimal Point = 4 or more, the
linear scale pitch 25.6 (

μm) can be expressed in an integral num-

ber. Therefore, set to 4.

No. 6

Linear Scale
Pitch

user units

(0.1

μm)

256

1 reference unit = 0.1 (

μm) because Number of Digits below

Decimal Point = 4. Therefore, set to 256 (0.1

μm)

No. 34 Rated Speed

0.1 m/s

15

Set to 15: The value of linear motor rated speed 1.5 (m/s) con-
verted in units of 0.1 m/s.

No. 36

Number of
Pulses per
Linear Scale
Pitch

pulse/ linear

scale pitch

2

Set to the result of division: Pn281 (Encoder Output Resolution)
÷ 4

( In this example, 8

÷ 4 = 2)

Fixed Parameter

Setting Unit

Set Value

Description

No. 4

Reference Unit
Selection

–

pulse

–

No. 5

Number of Digits
below Decimal
Point

–

–

This parameter is invalid when "pulse" is selected for Reference
Unit.

No. 6

Linear Scale
Pitch

μm

256

When "pulse" is selected for Reference Unit, the setting unit of
this parameter is fixed to "

μm". However, the linear scale pitch

25.6 (

μm) cannot be expressed in an integral number in this set-

ting unit.
Therefore, adjust the linear scale pitch by multiplying by 10 and
set to the result of multiplication: 256.

No. 34 Rated Speed

0.1m/s

150

The value of the linear motor rated speed 1.5 (m/s) converted in
0.1 m/s is 15. However, the actual linear scale pitch multiplied
by 10 is set for Linear Scale Pitch. To keep equivalence, set to
the value of the actual rated speed multiplied by 10: 150.

No. 36

Number of
Pulses per
Linear Scale
Pitch

pulse/ linear

scale pitch

2

Set to the result of division: Pn281 (Encoder Output Resolution)
÷ 4
( In this example, 8

÷ 4 = 2)

Advertising