2 ) setting example 2 – Yaskawa JAPMC-MC2300 User Manual

Page 140

Advertising
background image

6.1 Example Setting of Motion Parameters for the Machine

6.1.8 Linear Scale Pitch and Rated Motor Speed

6-16

( 2 ) Setting Example 2

The following tables give setting examples for these linear motor, linear scale, and SERVOPACK specifications.

Linear Motor Specifications

• Rated motor speed

: 1.5 (m/s)

Linear Scale and SERVOPACK Specifications

• Linear scale pitch

: 25.6 (

μm)

• Serial converter resolution

: 256 (division)

For SGDM, SGDH, SGDS, and SGDV SERVOPACKs, the set value of SERVOPACK parameter Pn281
(Encoder Output Resolution) is actually used in place of the serial converter resolution.

• Pn281 (Encoder Output Resolution): 8 (pulses/(scale pitch

×

4)

Set Pn281 to a value of multiples of 4.

[ a ] Setting Example when Fixed Parameter No. 4 (Reference Unit Selection) is Set to 1: mm

[ b ] Setting Example when Fixed Parameter No. 4 (Reference Unit Selection) is Set to 0: pulse

Fixed Parameter

Setting Unit

Set Value

Description

No. 4

Reference Unit
Selection

mm

The actual reference unit is determined by settings of this
parameter and the number of digits below decimal point (fixed
parameter 5).
When Number of Digits below Decimal Point = 4,
1 reference unit = 0.0001 (mm) = 0.1 (

μm)

No. 5

Number of Digits
below Decimal
Point

4

When Number of Digits below Decimal Point = 4 or more, the
linear scale pitch 25.6 (

μm) can be expressed in an integral num-

ber. Therefore, set to 4.

No. 6

Linear Scale
Pitch

user units

(0.1

μm)

256

1 reference unit = 0.1 (

μm) because Number of Digits below

Decimal Point = 4. Therefore, set to 256 (0.1

μm)

No. 34 Rated Speed

0.1 m/s

15

Set to 15: The value of linear motor rated speed 1.5 (m/s) con-
verted in units of 0.1 m/s.

No. 36

Number of
Pulses per
Linear Scale
Pitch

pulse/ linear

scale pitch

2

Set to the result of division: Pn281 (Encoder Output Resolution)
÷ 4

( In this example, 8

÷ 4 = 2)

Fixed Parameter

Setting Unit

Set Value

Description

No. 4

Reference Unit
Selection

pulse

No. 5

Number of Digits
below Decimal
Point

This parameter is invalid when "pulse" is selected for Reference
Unit.

No. 6

Linear Scale
Pitch

μm

256

When "pulse" is selected for Reference Unit, the setting unit of
this parameter is fixed to "

μm". However, the linear scale pitch

25.6 (

μm) cannot be expressed in an integral number in this set-

ting unit.
Therefore, adjust the linear scale pitch by multiplying by 10 and
set to the result of multiplication: 256.

No. 34 Rated Speed

0.1m/s

150

The value of the linear motor rated speed 1.5 (m/s) converted in
0.1 m/s is 15. However, the actual linear scale pitch multiplied
by 10 is set for Linear Scale Pitch. To keep equivalence, set to
the value of the actual rated speed multiplied by 10: 150.

No. 36

Number of
Pulses per
Linear Scale
Pitch

pulse/ linear

scale pitch

2

Set to the result of division: Pn281 (Encoder Output Resolution)
÷ 4
( In this example, 8

÷ 4 = 2)

Advertising