1 parameter settings for finite length axes, Caution – Yaskawa JAPMC-MC2300 User Manual

Page 277

Advertising
background image

10.3 Absolute Position Detection for Finite Length Axes

10.3.1 Parameter Settings for Finite Length Axes

10-6

10.3 Absolute Position Detection for Finite Length Axes

This section describes the procedure for setting parameters and precautions on setting zero-point and turning ON the
power supply when using the axis as a finite length axis.

10.3.1 Parameter Settings for Finite Length Axes

The following parameters must be set to enable the absolute position detection function when using an axis as a finite

length axis..

( 1 ) Machine Controller Fixed Parameters for Absolute Position Detection

The parameters for which

precautions are provided must be set referring to

10.3.2 Detailed Descriptions on Parameter Settings for Finite Length Axes on
page 10-8. Set these parameters carefully. If they are not set correctly, the cur-
rent position may not be correct after the power is turned ON. Machine damage
may occur.

Fixed Parame-

ter No.

Name

Setting/Range

Units

Reference Caution

1, bit 0

Axis Selection

0: Finite length axis,
1: Infinite length axis

10.3.2 ( 1 )

22

Pulse Counting
Mode Selection

0: Sign mode *1
1: Sign mode *2
2: Up/Down mode *1
3: Up/Down mode *2
4: A/B mode *1
5: A/B mode *2
6: A/B mode *4

10.3.2 ( 3 )

30

Encoder Selection

• Incremental encoder
• Absolute encoder
• Absolute encoder

(used as incremental encoder)

10.3.2 ( 2 )

36

Number of Pulses
per Motor Rotation

1 to 2

31

−1

Set the value after multiplication. (For a
16-bit encoder, set 2

14

= 16384.)

pulse

10.3.2 ( 3 )

38

Maximum Number
of Absolute Encod-
er Turns Rotation

0 to 2

31

−1

1 = 1 rota-
tion

10.3.2 ( 4 )

CAUTION

Advertising