Appendix C Fixed Parameter Setting According to Encoder Type and Axis Type

A-10

Appendix C Fixed Parameter Setting According to Encoder Type and

Axis Type

The method of setting or changing the coordinate zero point differs depending on the encoder type, motor type, and
axis type (infinite length axis or finite length axis) to be used. Use the flowchart below to correctly set the fixed param-
eter according to your application.

Absolute encoder ?

NO

YES

Infinite length axis ?

NO

YES

Direct-drive motor ?

NO

YES

Direct-drive motor ?

YES

NO

Infinite length axis ?

START

NO

YES

Simple ABS

applicable ?

YES

NO

Fixed Parameter Setting

No.1, bit 0 = 0

(Finite length axis)

No.1, bit 0 = 0

(Finite length axis)

No.1, bit 0 = 1

(Infinite length axis)

+

No.1, bit 9 = 1

(Simple ABS enabled)

No.1, bit 0 = 1

(Infinite length axis)

+

No.1, bit 9 = 1

(Simple ABS enabled)

No.1, bit 0 = 1

(Infinite length axis)

+

No.1, bit 9 = 0

(Simple ABS disabled)

No.1, bit 0 = 1

(Infinite length axis)

Encoder Type

Incremental

encoder

Absolute

encoder

Absolute

encoder

Absolute

encoder

Absolute

encoder

Motor Type

Any type

Incremental

encoder

Any type

Any type

other than

direct-drive

motor

Direct-drive

motor

Any type

other than

direct-drive

motor

Any type

other than

direct-drive

motor

Advertising