3.3 SVA Definition

3.3.1 Opening the SVA Definition Window

3-7

3

Setup

3.3 SVA Definition

The SVA definition file defines the motion parameters (motion fixed parameters, motion setting parameters, and
motion monitoring parameters) to control the motion axes such as the SERVOPACK.

Refer to 5 Motion Parameters on page 5-1 for details on the motion parameters.

3.3.1 Opening the SVA Definition Window

Open the SVA Definition Window by the following procedure.

1.

Select SVA-01 in the Controller field in the Module Configuration Window (refer to 3.2.2 Opening the
Module Configuration Window
on page 3-4), and then double-click the slot number cell of the SVA-01
Module in the Module Details field.

The Create New Confirmation Dialog Box will open. Click OK to display the Fixed Parameters Tab of the SVA
Definition Window.

2.

Select the axis to be set or monitored from the Axis pull-down list, and select the connected motor
type, rotary type or linear type, from the Servo Type pull-down list.

If the setting in Servo Type is switched from Rotary to Linear, or vice-versa, some of the displayed parameters
will change. Refer to 5 Motion Parameters on page 5-1 for details.