7.2 Motion Command Details

7.2.3 Zero Point Return (ZRET)

7-48

Parameters to be Set

Parameter

Name

Setting

Fixed Parameter

No.1, Bit 5

Deceleration LS
Inversion Selection

Set whether or not to invert the polarity of DI_2 signal that is used for
HOME signal.
0: Do not invert
1: Invert
However, the deceleration limit switch signal for zero point return
(OW

05, bit 8) will not be inverted even if this bit is set to 1 (Invert).

OW

03,

Bits 0 to 3

Speed Unit Selection

Select the setting unit for OL

10 (Speed Reference Setting), OL

3E

(Approach Speed), and OL

40 (Creep Rate).

0: Reference unit/s
1: 10

n

reference units/min

2: Percentage of rated speed (1 = 0.01%)
3: Percentage of rated speed (1 = 0.0001%)

OL

10

Speed Reference
Setting

Set the positioning speed to use after detecting the phase-C pulse. The sign
is ignored.
The travel direction will depend on the sign of the Zero Point Return Travel
Distance.
Setting to 0 or a negative value will result in an error.

OW

18

Override

This parameter allows the travel speed to be changed without changing the
Speed Reference Setting (OL

10). The setting can be changed during

operation.
Setting range: 0 to 32767 (0 to 327.67%)
Setting unit: 1 = 0.01%

OW

3C

Zero Point Return
Method

14: HOME LS & Phase-C Pulse Method

OL

3E

Approach Speed

Set the speed to be used at zero point return start.
The travel direction depends on the sign of the approach speed.
Setting to 0 will result in an error.

OL

40

Creep Rate

Set the speed and travel direction after the HOME signal is detected.
Setting to 0 will result in an error.

OL

42

Zero Point Return Travel
Distance

Set the travel distance from the point where a phase-C pulse is detected.
The travel direction will depend on the sign.