2.4.2 Connection Procedure for 24-V Input Cable
Prepare a 0.2 mm
2
to 0.51 mm
2
(AWG24 to AWG20) twisted-pair cable. Use the following connection procedure.
1.
Remove the sheath to approximately 6.5 mm from the cable end.
2.
Remove the plug from the CN3 connector on the SVA-01 Module.
3.
Insert the bare core of the cable into the opening of the plug and then tighten the secrews to a tighten-
ing torque of approximately 0.2 to 0.25 N
x
m.
Pin No.
Signal
Name
Name
2
24V
+24 VDC input
1
0V
0V
Core
Sheath
6.5 mm
+ side (pin number 2)
− side (pin number 1)