8.1 Switchable Motion Commands

8.1.11 Switching from TRQ

8-33

8

Switching Commands during Execution

TRQ

FEED

(cont’d)

(2) When Not Using the Accel/Decel Filter for FEED Command

STEP

TRQ will immediately switch to STEP, and the control mode will be changed from torque/
thrust control mode to position control mode.

STEP switched from TRQ starts its operation with the empty accel/decel filter.
Therefore, when the accel/decel filter is set for STEP command, the speed
will not smoothly change, and the distribution will be started from the state
Speed = 0 (see (1).) To change the speed smoothly, do not set the filter for
STEP command (see (2).)

(1) When Using the Accel/Decel Filter for STEP Command

(2) When Not Using the Accel/Decel Filter for STEP Command

Switched From

Switched To

Operation

TRQ

FEED

TRQ

FEED

Torque
control mode

Position control mode

TRQ

FEED

The speed will smoothly change.
The speed at the time the motion
command is switched will increase/
decrease until it reaches the FEED target
speed.

The accel/decel filter will be cancelled.

Motion command

Motion command
response

Distribution will start from the state
Speed = 0 since the accel/decel
filter is empty.

TRQ

Motion command

Motion command
response

STEP

TRQ

STEP

Torque
control mode

Position control mode

TRQ

STEP

TRQ

STEP

TRQ

STEP

Torque
control mode

Position control mode

TRQ

STEP

The speed will smoothly change.
The speed at the time the motion com-
mand is switched will increase/decrease
until it reaches the STEP target speed.

The accel/decel filter will be cancelled.

Motion command

Motion command
response