10.4 Absolute Position Detection for Infinite Length Axes

10.4.6 Infinite Length Position Control without Simple Absolute Positions

10-24

Use the following flowchart to store values in buffers.

High-speed scan drawing

starts

Toggle Buffer Enabled Flag is

set to 1.

Toggle Buffer Enabled Flag is

set to 0.

Copy the monitoring parameter

value and paste it in Buffer 0.

Toggle Buffer Enabled Flag is

set to 1.

Copy the monitoring parameter

value and paste it in Buffer 1.

End of

high-speed scan drawing

YES

NO

YES

NO

YES

NO

1st scan after the drawing starts ?

Operation is not ready and

an alarm is occurring ?

Toggle Buffer Selection Flag is

set to 1 ?

Position Data Save Request Flag is set to 0.

NO

YES

Zero Point Setting Completed

status ON ?

Position Data Save Request Flag is set to 1.

YES

NO

Zero point setting completed and

Position Data Save Request

Flag is set to 1 ?