6.1 Example Setting of Motion Parameters for the Machine

6.1.5 Speed Reference

6-10

( 2 ) Speed Reference (OL††10) Setting Examples

• Fixed parameter No. 5: Number of digits below decimal point = 3
• Fixed parameter No. 34: Rated motor speed = 3000 R/min
• Fixed parameter No. 36: Number of pulses per motor rotation = 16384 pulse/R (the value before multiply by 4)

The following table shows examples of settings for Speed Reference Setting (OL††10) to obtain the target feed speed

(reference speed).

( 3 ) Override (OW††18) Setting Example

The Override parameter (OW††18) can set the speed as a percentage (output ratio) of the target feed speed, in 0.01%
units. Override is set independently of Reference Unit, Number of Digits below Decimal Point, and other parameters.
A typical example of a Override setting is shown below.
Setting Example

Output ratio 25%: 25

÷ 0.01 = 2500

50%: 50

÷ 0.01 = 5000

75%: 75

÷ 0.01 = 7500

100%: 100

÷ 0.01 = 10000

OW††03, bits 0 to

3:

Speed Unit

Selection

Fixed Parame-

ter No. 4: Refer-

ence Unit

Setting

Setting Unit for

OL††10 Speed

Reference

Setting

Target Feed

Speed

Example

Set Value for OL††10 Speed Reference Setting

(Unit Conversion Method)

0

(Reference unit/s)

pulse

pulse/s

50 (R/s)

= 50 (R/s)

× 65536 (pulses/R)

= 3276800 (pulse/s)

Set value: 3726800

1500
(R/min)

= 1500 (R/min)

÷ 60 × 65536 (pulses/R)

= 1638400 (pulse/s)

Set value: 1638400

mm
( 1 reference
unit = 0.001
mm)

Reference unit/
s (= 0.001
mm/s)

500 (mm/s)

= 500 (mm/s)

× 1000 (reference units/mm)

= 500000 (reference units/s (=0.001 mm/s))

Set value: 500000

900
(mm/min)

= 900 (mm/min)

÷ 60 × 1000 (reference units/

mm)
= 15000 (reference units/s) (=0.001 mm/s))

Set value: 15000

1

(10

n

reference

units/min)

n = Number of dig-

its below decimal

point (= 3)

pulse

1000 pulses/
min
(Fixed to 1000
regardless of
value n)

50 (R/s)

= 50 (R/s)

× 60 × 65536 (pulses/R) ÷ 1000 (fixed)

= 196608 (pulse/min)

Set value: 196608

1500
(R/min)

= 1500 (R/min)

× 65536 (pulses/R) ÷ 1000

(fixed)
= 98304 (pulses/min)

Set value: 98304

mm
(1 reference
unit = 0.001
mm)

mm/min
(=10

3

refer-

ence units/min)

500 (mm/s)

= 500 (mm/s)

× 60

= 30000 (mm/min (=10

3

reference units/min)

Set value: 30000

900
(mm/min)

= 900 (mm/min)

Set value: 900

2

0.01%

0.01%

50 (R/s)

= 50 (R/s)

× 60 ÷ 3000 (R/min) × 10000 (0.01%)

= 10000 (0.01%)

Set value: 10000

1500
(R/min)

= 1500 (R/min)

÷ 3000 (R/min) × 10000 (0.01%)

= 5000 (0.01%)

Set value: 5000

Advertising