5.4 MP2000 Series Machine Controller Parameter Details

5.4.3 Motion Monitoring Parameter Details

5-43

5

Motion Parameters

( 34 ) Stop Distance

5.4.3 Motion Monitoring Parameter Details

The following tables provide details of motion monitoring parameters.

Refer to 5.3.3 Monitoring Parameter List on page 5-13 for a list of motion monitoring parameters.
Register number IW

00 indicates the leading input register number + 00. Other register numbers listed below

indicate input register numbers in the same way.
Refer to 5.1.1 Motion Parameter Register Numbers for MP2000 Series Machine Controllers on page 5-2 for informa-
tion on how to find the leading input register number.

( 1 ) Drive Status

( 2 ) Over Range Parameter Number

OL

6E

System Reservation (Stop Distance)

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

0

Description

Used in combination with MPOS as the software limit detection condition.

This parameter can be used in the normal operation mode and in the simulation mode.

Refer to11.3.2 Software Limit Detection Function on page 11-13 for details.

Position

Phase

Speed Torque

IW

00

RUN Status

Range

Unit

Description

Bit 0

Motion Controller Operation Ready

0: Operation not ready
1: Operation ready

This bit turns ON when RUN preparations for the Motion Module have been completed.
This bit will be OFF under the following conditions:

• Major damage has occurred.
• Axis that is not used was selected.
• Motion fixed parameter setting error
• Motion fixed parameters are being changed.

Bit 1

Running (Servo ON)

0: Stopped
1: Running (Servo ON)

This bit is ON while the axis is in Servo ON status.

Bit 3

Servo Ready

0: Servo not ready
1: Servo ready

This bit is ON when all of the following conditions are satisfied.

• The main power supply for the SERVOPACK is ON.
• There are no alarms in the SERVOPACK.

IW

01

Parameter Number when Range Over is Generated

Range

Unit

0 to 65535

Description

Stores the number of a parameter set outside the setting range.

• Setting parameters: 0 or higher
• Fixed Parameters: 1000 or higher

This parameter stores the number of the setting or fixed parameter that exceeds the setting range either individually or in
combination with the settings of other parameters.
When motion fixed parameters are used, the parameter stores the parameter number plus 1000.