1 system startup flowchart – Yaskawa JAPMC-MC2300 User Manual

Page 275

Advertising
background image

10.2 Setting Procedure of Absolute Position Detection Function

10.2.1 System Startup Flowchart

10-4

10.2 Setting Procedure of Absolute Position Detection Function

This section explains the procedure for setting the Absolute Position Detection Function.

10.2.1 System Startup Flowchart

Start up the system using the following procedure.

* If the system does not satisfy the conditions described in 10.4.1 ( 2 ) Conditions to Enable the Simple Absolute Infi-

nite Axis Position Control on page 10-14 when using the axis as an infinite length axis, the Machine Controller car-
ries out the operation without using simple absolute length position control.

After the steps 2 to 4 described above are successfully completed, the absolute position detection system will be ready
for operation.

Always perform the startup procedure of the absolute position detection system in the following situations.

• When starting up the absolute position detection system for the first time
• When the Servomotor is changed
• When an absolute encoder-related alarm occurs

1

Check Devices

Check to see if the SERVOPACK, Servomotor, and cables are the right products and models for the absolute encoder.

2

Initialize the Absolute Encoder

Follow the setup procedure to set the absolute encoder to default values.
(

10.2.2 Initializing the Absolute Encoder on page 10-5, and Appendix B Initializing the Absolute Encoder on page A-

5)

3

Setting Parameters Related to the Machine Controller and the SERVOPACKs

Set all parameters related to the Absolute Position Detection Function of the Machine Controller and SERVOPACKs.
The setting procedure for a finite length axis is different from that for an infinite length axis.

When using the axis as a Finite
Length Axis

10.3.1 Parameter Settings for

Finite Length Axes on page 10-6

10.3.2 Detailed Descriptions on

Parameter Settings for Finite
Length Axes
on page 10-8

When using the axis as an Infinite Length Axis

10.4.1 ( 2 ) Conditions to Enable the Simple Absolute Infinite Axis Position
Control
on page 10-14

*

With simple absolute infinite length
position control

10.4.2 Parameters Setting for Sim-

ple Absolute Infinite Length Posi-
tion Control
on page 10-16

Without simple absolute infinite
length position control

*

10.4.6 Infinite Length Position

Control without Simple Absolute
Positions
on page 10-22

4

Zero Point Setting

Set the zero point as well as the absolute zero point, that is, the machine coordinate zero point.
The setting procedure for a finite length axis is different from that of an infinite length axis.

When using the axis as a Finite
Length Axis

10.3.3 Setting the Zero Point for a

Finite Length Axis on page 10-10

With simple absolute infinite length
position control

10.4.4 Setting the Zero Point and

Turning ON Power as Simple
Absolute Positions
on page 10-20

Without simple absolute infinite
length position control

*

10.4.6 ( 3 ) Setting the Zero Point

for an Infinite Length Axis without
Simple Absolute Positions
on page
10-22

Advertising