6 restrictions for feedback pulse inputs – Yaskawa JAPMC-MC2300 User Manual

Page 44

Advertising
background image

2.6 Restrictions for Feedback Pulse Inputs

2.6.1 Restrictions for SERVOPACK Pulse Output Frequency

2-18

2.6 Restrictions for Feedback Pulse Inputs

2.6.1 Restrictions for SERVOPACK Pulse Output Frequency

The upper limit to the SERVOPACK pulse output frequency is shown below.

ΠHowever; Motor Speed at a Divided Output Pulse Frequency of 1.6 MHz = 1.6

× 10

6

× 60 ÷ Pn212 set value

The following tables show the relationship between the number of encoder bits and the maximum speed for a pulse fre-
quency of 1.6 MHz output by

Σ-II/Σ-III/Σ-V SERVOPACK.

Application must be within the ranges shown in these tables when a

Σ-II/Σ-III/Σ-V SERVOPACK is connected to the

SVA-01 Module.

„

When connecting a

Σ-II SERVOPACK

„

When connecting a

Σ-III or a Σ-V SERVOPACK

Upper Limit (actual value) of Phase-A/B Divided Output Pulse Frequency fo

Σ-II/Σ-III/Σ-V SERVOPACK =

1.6 MHz (before multiplication)

Encoder Bits

Pn201 Setting Range

Pn201 Setting

Example

Motor Speed (min

-1

) at a Divided Output

Pulse Frequency of 1.6 MHz

17 bits

16 to 16384 (in increments of pulses)

16384

6000

20 bits

16 to 16384 (in increments of pulses)

16384

6000

Encoder Bits

Pn212 Setting Range

Pn212 Setting

Example

Motor Speed (min

-1

) at a Divided Output

Pulse Frequency of 1.6 MHz

17 bits

16 to 16384 (in increments of pulses)

16384

6000

16386 to 32768 (in increments of
pulses)

32768

3000

20 bits

16 to 16384 (in increments of pulses)

16384

6000

16386 to 32768 (in increments of
pulses)

32768

3000

32772 to 65536 (in increments of
pulses)

65536

1500

65544 to 131072 (in increments of
pulses)

131072

750

131088 to 262144 (in increments of
pulses)

262144

375

Advertising