10.4 Absolute Position Detection for Infinite Length Axes

10.4.6 Infinite Length Position Control without Simple Absolute Positions

10-27

10

Absolute Position Detection

Use the following flowchart for storing the position data in the setting parameters and for Request ABS Rotary Pos.
Load requests.

High-speed scan drawing

starts

1st scan after the drawing starts ? Or,

Servo power reset signal is set to 1?

Position Data Re-setup Request Flag is set to 1

Operation ready and Position Data

Re-setup Request Flag is set to 1 ?

ABS System Infinite Length Position
Control Data Initialization Completed

Flag is set to 0 ?

Toggle Buffer Enabled Flag is set to 1 ?

Toggle Buffer Selection Flag is

set to 1 ?

Copy the value of Buffer 1 and
and paste it in the setting
parameter.

ABS System Infinite Length

Position Control Data Initialization

Request Flag is set to 1

Position Data Save Request Flag is

set to 1

Copy the value of Buffer 0 and
paste it in the setting
parameter.

End of

high-speed scan drawing

ABS System Infinite Length

Position Control Data Initialization

Request Flag is set to 0

Position Data Re-setup Request Flag is set to 0

NO

YES

NO

YES

NO

YES

NO

YES

NO

YES

Position Data Re-setup Enabled Flag is

set to 0

Advertising