2 ) mode 1 ( 3 ) function 1 – Yaskawa JAPMC-MC2300 User Manual

Page 99

Advertising
background image

5.4 MP2000 Series Machine Controller Parameter Details

5.4.2 Motion Setting Parameter Details

5-27

5

Motion Parameters

( 2 ) Mode 1

( 3 ) Function 1

OW

01

Mode Setting 1

Setting Range

Setting Unit

Default Value

0000H

Description

Bit 0

Excessive Deviation Error Level Setting

Set whether excessively following errors are treated as warnings or as alarms.

0: Alarm (default): Axis stops operating when an excessively following error is detected.
1: Warning: Axis continues to operate even if an excessively following error is detected.

When the absolute value of deviation amount

>

40000000H, Excessive Deviation alarm (IW

04, bit 9) will

occur and the execution of motion command will be ended in error regardless of the setting of this bit.
Related Parameters
OL

22: Error Count Alarm Detection

IL

02, bit 0: Warning (Excessive Deviation)

IL

04, bit 9: Alarm (Excessive Deviation)

Bit 2

Speed Compen. in Pos. Mode

Set whether or not to enable the speed compensation during position control.

0: Disabled (default)
1: Enabled

Setting this bit to 1 (Enabled) will validate the following two speed compensation values.
OW

31: Speed compensation

OL

16: Secondly speed compensation

OW

03

Function Setting 1

Setting Range

Setting Unit

Default Value

0011H

Description

Bit 0 to

Bit 3

Speed Unit Selection

Set the unit for speed references.

0: Reference unit/s
1: 10

n

reference unit/min (default) (n = number of decimal places/fixed parameter 5)

2: 0.01%
3: 0.0001%

Refer to 6.1.5 Speed Reference on page 6-9 for setting examples when also setting of the
combination with the number of digits below the decimal point.

Bit 4 to

Bit 7

Acceleration/Deceleration Unit Selection

Set whether to specify acceleration/deceleration rates (reference unit/s

2

) or acceleration/deceleration time con-

stants (ms) for acceleration/deceleration commands.

0: Reference units/s

2

1: ms (default)

Bit 8 to

Bit B

Filter Type Selection

Set the acceleration/deceleration filter type.

0: Filter none (default)
1: Exponential acceleration/deceleration filter
2: Moving average filter

Bit C to

Bit F

Torque Unit Selection

Set the unit for torque reference as a percentage of rated torque.

0: 0.01% (default)
1: 0.0001%

The unit for torque reference indicates the torque reference resolution, but not guarantees the
torque accuracy.

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Advertising