Yaskawa JAPMC-MC2300 User Manual

Page 98

Advertising
background image

5.4 MP2000 Series Machine Controller Parameter Details

5.4.2 Motion Setting Parameter Details

5-26

Description

Bit 4

Latch Detection Demand

0: OFF (default)
1: ON

When this bit is set to 1 (Latch Request ON), the position at the moment the latch signal turns ON will be
reported to the monitoring parameter IL

18 "Machine Coordinate System Latch Position."

When the position is detected and reported, bit 2 "Latch Completed" of the monitoring parameter IW

0C

"Position Management Status" will turn ON.
To detect the position again, reset this bit to 0 (OFF) and then set to 1 (ON) again.
Use bits 0 to 3 (Latch Detection Signal Selection) of the setting parameter OW

04 (Function Setting 2) to

set the latch signal to be used.

Do not set this bit to 1 (ON) while the motion commands “Zero Point Return,” “External Posi-
tioning,” or “Latch” are being executed. Otherwise, a warning may occur in the SERVOPACK.
Refer to 11.4.1 Modal Latch Function on page 11-15 for details of the latch function.

Bit 5

Absolute Position Reading Demand

0: OFF (default)
1: ON

Setting this bit to 1 (ON) allows the ladder program to start reading absolute data (at the rising edge). Reading
will be executed twice maximum, including one retry.

Refer to

11.4.3 Reading Absolute Data Online

on page 11-16 for details.

Bit 6

POSMAX Turn Number Presetting Demand

0: OFF (default)
1: ON

Preset the Number of POSMAX Turns (monitoring parameter IL

1E) to the value set for the Number of

POSMAX Turns Presetting Data (setting parameter OL

4C).

Set to 0 for linear type.

Bit 7

Request ABS Rotary Pos. Load

When an infinite length axis is used with an absolute encoder, this bit can be set to 1 to reset the position infor-
mation with the data (encoder position and pulse position) that was set when the power was last turned OFF.
When processing has been completed for this bit, the ABS Rotary Pos. LOAD Complete bit will be turned ON
in the Position Management Status (monitoring parameter IW

0C, bit 8).

0: OFF (default)
1: ON

Refer to 10.4.6 ( 4 ) [ b ] Turning the System Back ON (Turning the Servo Back ON) on page
10-26 for details.
Set to 0 for linear type.

Bit B

Integration Reset

0: OFF (default)
1: ON

Setting this bit to 1 (ON) will reset the position loop integral items for the SERVOPACK.

Bit F

Alarm Clear

0: OFF (default)
1: ON

At the rising edge of this bit, an alarm is cleared. Additionally, turns ON the /ALMRST signal connected to the
SERVOPACK to clear the SERVOPACK alarm.

The following alarm and warning cannot be cleared by Alarm Clear. Remove the cause of the
alarm.
IW

02, bit 2: Fixed Parameter Error

IW

04, bit 15: ABS Total Rev. Receive Error

Do not execute Alarm Clear during axis movement using motion commands. Using Alarm
Clear may affect axis movement.

OW

00

RUN Command Setting (cont’d)

Setting Range

Setting Unit

Default Value

0000H

Position

Phase

Speed Torque

Advertising