12.3 Motion Program Alarms

12.3.1 Motion Program Alarm Configuration

12-27

12

Troubleshooting

12.3 Motion Program Alarms

If the result of investigation using 12.1.2 MP2000 Series Machine Controller Error Check Flowchart on page 12-3
indicates that a motion program alarm has occurred, use the alarm code to determine the cause of the error.

12.3.1 Motion Program Alarm Configuration

Motion program alarms stored in the alarm output register (default: SW03268) are displayed as shown in the following
diagram.

Refer to the relevant Machine Controller user’s manual for information on finding the alarm output register.

12.3.2 Motion Program Alarm Code List

The motion program alarm codes are listed in the following table.

When displaying these on the register list, set the view mode to hexadecimal.

* The axis number is stored in bits 8 to 12 for axis alarms.

Alarm axis information (1 to 16)

Bit 15

Bit 12

Bit 8 Bit 7

Bit 0

Alarm code (Axis alarm when bit 7 turns ON.)

Alarm Code

Description

Correction

Program

alarms

0

No alarm

Check the specifica-

tions for the instruc-

tion that was being

executed in the motion

program when the

alarm occurred accord-

ing to the meaning of

the alarm code.

10h

Complete circle specified for radius designation

11h

Interpolation feed speed exceeded

12h

Interpolation feed speed not specified

13h

Range exceeded after acceleration/deceleration speed parameter conversion

14h

LONG_MAX exceeded for circular arc length

15h

No vertical specification for circular plane designation

16h

No horizontal specification for circular plane designation

17h

Specified axes exceeded

18h

Specified number of turns exceeded

19h

LONG_MAX exceeded for radius

1Bh

Emergency stop in progress

1Ch

LONG_MAX exceeded for linear interpolation block moving amount

1Dh

FMX not defined

1Eh

Address T out of range

1Fh

Address P out of range

20h

REG data error

21h

Function work duplication (Function work in second PFORK column was

used at a different nesting level.)

22h

Indirect register designation range error

23h

Overflow when converting reference unit

Axis

alarms*

80h

During use of logical axis prohibited

81h

Specifications exceeding POSMAX made for infinite length axis designation

82h

LONG_MAX exceeded for axis moving distance

84h

Motion command duplication

85h

Motion command response duplication

87h

VEL setting data out of range

88h

INP setting data out of range

89h

ACC/SCC/DCC setting data out of range

8Ah

T reference for MVT instruction is 0

8Bh

Instruction designated that cannot be executed for the Motion Module model

8Ch

Prohibition command executed when pulse distribution was not completed

8Dh

Motion command error end status