Mentor VIP AE AXI3/4 User Guide, V10.2b

58

SystemVerilog AXI3 and AXI4 Master BFMs
get_read_data_phase()

September 2013

AXI4 Example

// Declare a local variable to hold the transaction record.
axi4_transaction read_trans;

// Create a read transaction with start address of 0 and assign
// it to the local read_trans variable.
read_trans = bfm.create_read_transaction(0);

....

// Get the read data phase for the first beat of the
// read_trans transaction.
bfm.get_read_data_phase(read_trans, 0);

// Get the read data phase for the second beat of the
// read_trans transaction.
bfm.get_read_data_phase(read_trans, 1);