Aastra web ui – AASTRA 6700i series, 9143, 9480i, 9480i CT SIP Administrator Guide EN User Manual

Page 202

Advertising
background image

41-001343-01 Rev 03, Release 3.2.2

4-39

3

In the “STUN Port” field, enter the port number of the STUN server. You can enter up to 2 values

separated by a comma. The first value is the primary and the second value is the backup. For

example:

3478,3479

Default is 3478. Range of values are 0 to 65535.

4

Click

to save your changes.

Configure TURN on the IP Phone
5

In the “TURN Server” field, enter the IP address and/or qualified domain name of the TURN server in

your network. You can enter up to 2 values separated by a comma. The first value is the primary and

the second value is the backup. For example:

10.50.103.12, turnbackup.aastra.com.

The TURN configuration is only used for media (RTP traffic) that goes through the server - not for

signaling. (For signaling, you need to enable Rport if the NAT device does not recognized SIP).

The TURN configuration applies globally to each phone.

If you configure both STUN and TURN on the phone, it discovers what type of NAT device is between

the phone and the public network. If the NAT device is full cone, restricted cone, or port restricted

cone, the phone uses STUN. If the NAT device is symmetric, the phone uses TURN. If you configure

TURN only, the phone uses TURN with the NAT discovery process. TURN is compatible with all

types of NAT devices but can be costly since all traffic goes through a media relay (which can be

slow, can exchange more messages, and requires the TURN server to allocate bandwidth for calls).

Note: The NAT IP configuration parameter takes precedence over the STUN and TURN parameters.

6

In the “TURN Port” field, enter the port number of the TURN server. You can enter up to 2 values

separated by a comma. The first value is the primary and the second value is the backup. For

example:

3479,3480

Default is 3479. Range of values are 0 to 65535.

7

(Optional) In the “TURN User ID” field, enter the username that a user must enter when accessing an

account on the TURN server. For example, 0412919146.

Valid values are up to 63 alphanumeric characters.

8

(Optional) In the “TURN Password” field, enter the password that a user must enter when accessing

an account on the TURN server. For example, 42447208233b8b8b8a234.

Valid values are up to 63 alphanumeric characters.

9

Click

to save your changes.