A-255

WatchDog Settings

Examples

Enter a debug level value in the “Debug Level” field for a module.

Example 1

To turn two or more debug levels on at the same time, you add the value

associated with each level. For example,

Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7

log module linemgr: 7

log module user interface: 7

log module sip: 7

In the above example, fatal errors, general errors, and warnings are

logged for the line manager, user interface, and SIP call control modules.

Example 2

Functions and Info = 16 + 32 = 48

log module dis: 48

log module net: 48

log module snd: 48

In the above example, functions and general information are logged for

the display drivers, network, and sound modules.

Example 3

log module rtpt: 0

log module ind: 65535

In the above example, all debug levels are OFF for the Real Time

Transport module. All debug levels are ON for the indicator module.

You can set the Module/Debug Levels using the configuration files or the

Aastra Web UI.

Parameter
watchdog enable

WatchDog
(in Web UI)

Configuration Files

aastra.cfg, <model>.cfg, <mac>.cfg

Aastra Web UI

Advanced Settings->Troubleshooting

Description

Enables/disables the use of the WatchDog task for the IP Phones.

Format

Boolean

Default Value

1 (enabled)

Range

0 (disabled)

1 (enabled)

Example

watchdog enable: 0