Ction, Broadsoft client management system (cms), With broadsoft client management system (cms) – AASTRA 6700i series, 9143, 9480i, 9480i CT SIP Administrator Guide EN User Manual

Page 622

Advertising
background image

41-001343-01 Rev 03, Release 3.2.2

5-345

Authentication Support for HTTP/HTTPS Download Methods, used with Broadsoft
Client Management System (CMS)

The IP phones support HTTP/HTTPS digest authentication as defined in

RFC 2617. (The HTTP client supports digest authentication; the HTTP server does not; the HTTP

server supports basic authentication). This feature allows the phones to interoperate with

Broadsoft’s CMS phone configuration tool.

Using the configuration files, you can enable/disable the following parameter to display a LOG IN

softkey which allows the HTTP/HTTPS server to perform digest authentication:

http digest force login

- specifies whether or not to display the LOG IN softkey on the IP

Phone UI screen. Valid values are 0 (disabled) or 1 (enabled). Default is 0 (disabled).

If the “http digest force login” parameter is set to 1 (enabled), after the phone boots, the LOG IN

softkey displays on the phone’s LCD. If the user presses this softkey, a username/password screen

displays, allowing the user to enter the configured username and password that is sent to the

HTTP/HTTPS server for digest authentication by the server. By default, username is “aastra” and

password is “aastra”. You can enter the username and password in two ways:
• Using the configuration files, you can change the default values for the following parameters:

http digest username - specifies the username to use for HTTP/HTTPS digest

authentication.

http digest password - specifies the password to use for HTTP/HTTPS digest

authentication.

• By enabling the “http digest force login” parameter (setting to 1) - the phone displays the

LOG IN key so the user can enter the default username/password via the IP Phone UI.

Configuring Broadsoft CMS Support via the Configuration Files

Configure Broadsoft CMS support on the IP Phone using the following parameters in the

configuration files:

http digest force login

http digest username

http digest password

Configuration Files

For specific parameters you can set in the configuration files, see Appendix A, the section,

“HTTP/HTTPS

Authentication Support for Broadsoft CMS”

on

page A-99.