Sip keep alive support – AASTRA 6700i series, 9143, 9480i, 9480i CT SIP Administrator Guide EN User Manual
Page 767
A-36
41-001343-01 Rev 03, Release 3.2.2
SIP Keep Alive Support
Parameter –
sip turn user
Aastra Web UI:
Advanced Settings->Network->
Advanced Network Settings
Configuration Files aastra.cfg, <model>.cfg, <mac>.cfg
Description
Username that a user must enter when accessing an account on the
TURN server.
Note: The NAT IP configuration parameter takes precedence over the
STUN and TURN parameters.
Format
Alphanumeric characters
Default Value
Not Applicable
Range
Up to 63 alphanumeric characters
Example
sip turn user: 0412919146
Parameter –
sip turn pasx
Aastra Web UI:
Advanced Settings->Network->
Advanced Network Settings
Configuration Files aastra.cfg, <model>.cfg, <mac>.cfg
Description
Password that a user must enter when accessing an account on the
TURN server.
Note: The NAT IP configuration parameter takes precedence over the
STUN and TURN parameters.
Format
Alphanumeric characters
Default Value
Not Applicable
Range
Up to 63 alphanumeric characters
Example
sip turn pass: 42447208233b8b8b8a234
Parameter –
sip keepalive timer
Configuration Files aastra.cfg, <model>.cfg, <mac>.cfg
Description
This value is how many seconds to wait before sending a SIP UDP
keep alive packet to the configured SIP servers. A zero value disables
this feature.
Note: This is only for UDP transport protocol.
Format
Integer
Default Value
0
Range
Any positive integer
Example
sip keepalive timer: 6