Adding an ArmorStart to RSLogix 5000 Chapter 5

Table 16 - Bulletin 280E/281E Produced Assembly

Status Tag Explanation

Controller Input/Status Tags

Tag Description/Use

Fault

Communication Fault between PLC and Device (all 1's =

Fault, all 0's = Normal)

TripPresent

Fault exisits with unit

WarningPresent

Warning of potential fault

RunningForward

Motor commanded to run forward

RunningReverse

Motor commanded to run reverse

Ready

Control Power and 3-phase present

In0

Input 0

In1

Input 1

In2

Input 2

In3

Input 3

Hand

HOA is in Auto mode

DisconnectClosed

Disconnect is closed

Pt00DeviceOut

DeviceLogix network output status

Pt01DeviceOut

DeviceLogix network output status

Pt02DeviceOut

DeviceLogix network output status

Pt03DeviceOut

DeviceLogix network output status

Pt04DeviceOut

DeviceLogix network output status

Pt05DeviceOut

DeviceLogix network output status

Pt06DeviceOut

DeviceLogix network output status

Pt07DeviceOut

DeviceLogix network output status

Pt08DeviceOut

DeviceLogix network output status

Pt09DeviceOut

DeviceLogix network output status

Pt10DeviceOut

DeviceLogix network output status

Pt11DeviceOut

DeviceLogix network output status

Pt12DeviceOut

DeviceLogix network output status

Pt13DeviceOut

DeviceLogix network output status

Pt14DeviceOut

DeviceLogix network output status

LogicEnabled

DeviceLogix is enabled

ProducedWord0Param

Data reference by Parameter 13

ProducedWord1Param

Data reference by Parameter 14

ProducedWord2Param

Data reference by Parameter 15

ProducedWord3Param

Data reference by Parameter 16