Rockwell Automation 284E ArmorStart with EtherNet/IP - User Manual User Manual
Page 340
Advertising

340
Rockwell Automation Publication 280E-UM001B-EN-P – July 2012
Appendix E StepLogic, Basic Logic and Timer/ Counter Functions
Table 55 - Digit 3 Settings
Setting
Accel/Decel
Parameters Used
StepLogic
Output State
Commanded Direction
0
1
OFF
FWD
1
1
OFF
REV
2
1
OFF
No Output
3
1
ON
FWD
4
1
ON
REV
5
1
ON
No Output
6
2
OFF
FWD
7
2
OFF
REV
8
2
OFF
No Output
9
2
ON
FWD
A
2
ON
REV
b
2
ON
No Output
Advertising