218

Rockwell Automation Publication 280E-UM001B-EN-P - July 2012

Chapter 9 Diagnostics

2. Select the Edit Tags tab at the bottom of the screen and create a

tag named Reset of the type BOOL (Boolean).

6.

Create a rung in ladder logic for executing the Type 1 Reset.
a. Add an XIC Input and assign it the BOOL tag Reset.

b. Add a Message (MSG) instruction that will be used to execute the

reset. The message instruction can be found in the Input/Output
instruction set tab.

c. The completed rung should look like the one below.

7.

Configure the message instruction:
a. Begin by double clicking on the tag name field and entering AS_Reset.

b. Right click on the tag name AS_Reset and select New “AS_Reset”.